The typical faults of the concrete mixing machine and the countermeasure
Jun 09, 2017
The main motor of the
concrete mixer can’t be started when you press down the
concrete mixer, the analysis of the reason: the first reason is the air compressor isn’t started or the pressure of the air feed system doesn’t reach the 0.4MPa. the second reason is the examination switch of the main machine or the emergency shut switch is not connected. The emergency shut switch not return to the original position. The fourth is the switch of the machine is not connected.
The five is the main machine stop signal is not recovered. The countermeasure: check the press air check signal(the pressure signal more than 0.4MPa must be send to the PLC, namely, does the I8.0 has the signal, if the I8.0 still has no the signal, you shall check the electric contact pressure gauge adjustment is normal or broken until there is the I8.0 signal. You shall check that the mixer maintenance protective switch signal is sent to the PLC, the I9.7 the signal, and then check emergency stop switch is properly reset, I0.1 the signal. 4, next, check that the main power switch is switched on, the I3.4 the signal. Finally, check out button is reset and the I5.2 is switched on. The concrete mixing machine manufactured by Haomei is of the high quality and the products have been sold to many places, gaining the appraise of the clients, if you have any need, please contact us!