* Hydraulic system pressure is not enough
* Other abnormal excess load on the arm
* Solenoid valve blocked or solenoid valves to burn out
Solution:
* If the maximum pressure of the valve value that indicates the value did not reach the arm work, should check whether the maximum pressure valve is not adjusted. If this does not rule out failure, indicates a damaged hydraulic pump, hydraulic pump should be replaced; the extra load is no longer acting on the arm.
* If in accordance with the preceding articles after inspection, the arm still does not work properly, you must check the instructions of a single control arm valve is working properly.
* Connection clearance
* The connection between pin and mount
* The thrust bearing between fixed and rotating parts
* The thrust bearing bolt release
Solution: replace the damaged part, lubrication frequency and ensure movement, replace thrust bearing, in accordance with the regulations tighten, tighten or replace the bolts.
* Valve block occurred because of dirt blocked
* Pump static level
* Brake disc wear
* Brake spring deformation
Solution: clean or replace the valve block, lifting a leg, keep the pump level, replace the brake disc, brake replacement springs.
* Lock valve block is not adjusting well, valve block is dirty or damaged
* Hydraulic cylinder leakage
* Adjustment or cleaning, replacement of the valve block, the replacement of seals, check that the tubing is damaged.
* Oil nozzle blocked or damaged
* Lubrication pipes due to dirt and block
Solution: change the oil mouth, remove the PIN, check for cause of pipe blocking and wear and clearance. Note: this may lead pin killed, pins with the jib rotation, PIN card is destroyed. Here are two ways to remove the PIN:
* Add grease injection inlet and connection to the PIN, and then remove the
* Add grease to the PIN, I still cannot remove, use heat removal, it must replace the pins and bushings.