First, the triple valve in pressure of the gas source cannot be adjusted
Rotating pressure reducing valve adjusting hand wheel, but pressure must not be adjusted.
1, pressure reducing valves-export direction reversed.
2, the valve core embedded foreign body or slip on the spool position there was something stuck.
3, pressure regulating spring, spring, diaphragm, valve on the rubber mats and other damage.
1 import and export, check valve installed in the correct direction.
Check the valve spool and parts 2, scrapping and cleaning up debris on the part.
3, about the damaged parts, then replace the pressure relief valve.
Second, air oil mist in the FRL does not oil drops or drops of oil are too small
Compressed air flow, but spray drops of oil or very small drops of oil.
1, import and export of oil mist direction reversed.
2, oil plug.
3, oil plug gasket or oil Cup gasket corruption, oil Cup cavities cannot be pressurized.
4, air passages become plugged, oil cups on the cavity pressure.
5, throttle valve does not open or open enough.
6, oil viscosity is too large.
1, check the import and export of oil mist installation directions.
2, occlude, dismantling, cleaning oil; replacement of gaskets and seals; clear channel.
3, adjust the throttle valve opening.
4, replacing small viscosity of lubricants.
Three, frequent compressor starts
In the course of work, frequent compressor starts.
1, air compressor pressure is too small.
2, pneumatic system leakage is serious.
1, check the air compressor pressure and adjust, and generally 0.2MPa.
2, check the tightness of the gas system to meet the requirements and to deal with the leak site.
On the four-cylinder magnetic switch does not close or is not closed
When the cylinder is closed or open when the magnet close to farewell switch, but POS switch does not close or is not closed
1, power failure;
2, poor wiring;
3, a magnetic switch mounting excursion;
4, cylinder surrounded by a strong magnetic field;
5, parts of the in-cylinder temperature is too high or the magnetic switch temperature above 70 degrees;
6, magnetic switch hit, desensitizing;
7 instantaneous break through the current, magnetic switches.
1, check that the power supply is normal;
2, check for loose wiring parts;
3, adjust the magnetic rehabilitation installation location;
4, plus magnetic Board.
5, cool.
6, replace the magnetic switch.
Copyright Haomei machinery equipment CO., LTD. all rights reserved. Sitemap Product Index Technical Support: HAOMEI